Check the possible causes and find out the solution!
Possible Causes
What You Can Do?
►
Insufficient blocking
Select appropriate serum as blocking buffer. Blocking for 1 hour at room temperature.
►
Interference from endogenous enzymes
Perform H2O2 or Levamisole quenching.
►
Non-specific binding from primary antibodies
Dilute primary or secondary antibody. Choose another IHC-validated primary antibodies.
►
Inadequate washing
Increase washing cycles/time. Increase salt/detergent concentration
for stronger washes.►
Non-specific binding from secondary antibodies
Perform secondary antibody incubation only. Use pre-adsorbed secondary antibody.
►
Non-specific binding from chromogen
Perform chromogen incubation only. Use other chromogen if necessary.
►
Interference from secondary antibody in multicolor staining
Make sure that the fluorochrome does not overlap with one another.
►
Autofluorescence issue
Make sure that there is no endogenous background caused by tissue itself. Check under fluorescence microscope prior to staining to identify autofluorescence.
-
Check the possible causes and find out the solution!
Possible Causes
What You Can Do?
►
Antigen retrieval too harsh
Optimize retrieval steps to give the best morphology.
►
Tissue sections peeled off slide
Dry samples for 2-4 hours at 60°C.
Tissue with high lipid content (eg breast tissues) should be dried for longer time.►
Sectioning issue
Cut thinner slides for better resolution: 3-5 μm. Use a new/sharper blade.
►
Autolysis has occurred
Fix samples as soon as possible.
Choose other fixatives to accelerate penetration.
Fixative perfusion might be necessary for larger tissues. -
Check the possible causes and find out the solution!
Possible Causes
What You Can Do?
►
Over fixation
Reduce fixation time. Perform antien retrieval to unmask epitopes.
►
Insufficient fixation
Increase fixation time or try other fixative.
►
Fixation process delayed
Fix immediately as tissue is extracted.
►
Permeabilization issue
For nuclear/cytoplasmic proteins, add permeabilization agent (eg Triton X-100, Saponin) in blocking and antibody incubation buffer.
For membrane/tight junction proteins, avoid permeabilization agent.►
Primary antibodies not suitable for IHC
Choose an IHC-validated primary antibodies.
►
Wrong secondary antibody used
Make sure that primary and secondary antibodies match one another.
►
Low expression of protein in tissue samples
Use signal amplification methods (eg: HRP Polymer ARG80982, ARG80967, ARG80966)
►
Insufficient deparafinization
Make sure that parafin is removed completely before staining.