Search Result - Kits

There are 1938 results for "elisa kit"
  • Arg8 Vasopressin ELISA Kit
  • Cat. No: ARG83003
  • Reactivity: Hu, Ms, Rat, Dog, Sheep
  • Application: ELISA
  • Specificity: Cross-Reactivity:
    [Arg8]-Vasopressin (Human, Mouse, Rat, Ovine, Canine): 100%; [Arg8]-Vasotocin: 54%; [Lys8]-Vasopressin (Human, Rat, Mouse, Ovine), Deamino-[D-Arg8]-Vassopressin, Oxytocin, LH-RH, ACTH (Human), alpha-ANP (1-28) (Human, Canine), Met-Enkephalin, PACAP38 (Human, Ovine, Rat) and PACAP27-NH2 (Human, Ovine, Rat): 0%.
  • Sample type: Plasma (Sample extraction is recommended)
  • Sensitivity: 0.04 ng/ml
  • Standard Range: 0.01 - 100 ng/ml
  • Detection Range: 0.04 - 0.51 ng/ml
  • Conjugation: HRP
  • C5a ELISA Kit
  • Cat. No: ARG80868
  • Reactivity: Hu, Pig, Rb, R. Mk
  • Application: ELISA
  • Sample type: Plasma (EDTA, citrate) and urine.
  • Sensitivity: 20 pg/ml
  • Standard Range: 0.1 - 10 ng/ml
  • Conjugation: HRP
  • LH-RH / Gn-RH ELISA Kit
  • Cat. No: ARG80913
  • Reactivity: Hu, Ms, Rat, Pig
  • Application: ELISA
  • Specificity: Cross-reactivity: LH-RH (Human, Porcine, Rat) (100%);
    LH-RH (Lamprey) (0%);
    LH-RH (Salmon) (0%);
    [D-Trp6, Des-Gly10]-LH-RH Ethylamide (0%);
    [D-Ala6, Des-Gly10]-LH-RH Ethylamide (0%);
    GAP (Human) (0%);
    GRF (Human) (0%);
    ACTH (Human) (0%)
  • Sample type: Blood collection, Plasma extraction, Tissue extraction and CSF extraction
  • Sensitivity: 0.05 ng/ml
  • Standard Range: 0 - 25 ng/ml
  • Detection Range: 0.05 - 1.16 ng/ml
  • Conjugation: HRP
  • Irisin ELISA Kit
  • Cat. No: ARG81195
  • Reactivity: Hu, Ms, Rat, Dog
  • Application: ELISA
  • Specificity: Irisin, Recombinant (Human, Rat, Mouse, Dog): 100%
    Irisin (aa. 1-112) (Human, Mouse, Rat, Dog): 100%
    FNDC5, isoform 4 recombinant (Human, Mouse, Rat, Dog): 9%
    Irisin precursor, C-terminal 48mer: Human FNDC5 (aa. 165-212); Mouse, Rat FNDC5 (aa. 162-209): 0%
    Irisin (aa. 42-95) (Human, Mouse, Rat, Dog): 0%
  • Sample type: plasma (EDTA) and serum
  • Sensitivity: 1.91 ng/ml
  • Standard Range: 0.1 - 1000 ng/ml
  • Detection Range: 1.91 - 18.0 ng/ml
  • Conjugation: HRP
  • Glucagon ELISA Kit
  • Cat. No: ARG81293
  • Reactivity: Hu, Ms, Rat, Pig
  • Application: ELISA
  • Specificity: No significant cross-reactivity or interference with the factors below was observed:Glucentin-Related Polypeptide (aa 21-50), Glucagon-Like Peptide 1 (aa 92-128) and Glucagon-Like Peptide 2 (aa 146-178).
  • Sample type: Serum, plasma or cell culture supernatants.
  • Sensitivity: 30 pg/ml
  • Standard Range: 62.5 - 4000 pg/ml
  • Conjugation: HRP
  • Mouse/Rat Insulin (Ultra sensitive) ELISA Kit
  • publication_list (1 Publications)
  • Cat. No: ARG81295
  • Reactivity: Ms, Rat
  • Application: ELISA
  • Specificity: Mouse / Rat Insulin: 100%
    Hamster Insulin: Detected
    Rat C-peptide, Rat pancreatic polypeptide, Porcine glucagon, Human Insulin like growth factor-I and II: Not Detected
  • Sample type: Serum, plasma and cell culture supernatants.
  • Sensitivity: 50 pg/ml (5 µl sample volume); 5 pg/ml (100 µl sample volume)
  • Standard Range: 0.1 - 6.4 ng/ml
  • Conjugation: HRP
  • Orexin A ELISA Kit
  • Cat. No: ARG81308
  • Reactivity: Hu, Ms, Rat, Bov
  • Application: ELISA
  • Specificity: Cross Reactivity:
    Orexin A (Human, Bovine, Mouse, Rat): 100%
    Orexin A (16-33), Orexin B (Human), Agouti-Related Protein (83-132)-Amide (Human), Neuropeptide (Human, Rat), α-MSH, Leptin (Human): 0%
  • Sample type: Serum and plasma
  • Sensitivity: 0.18 ng/ml
  • Standard Range: 0.01 - 100 ng/ml
  • Detection Range: 0.18 - 5.6 ng/ml
  • Conjugation: HRP
  • Peptide YY ELISA Kit
  • Cat. No: ARG81309
  • Reactivity: Ms, Rat, Dog, Pig
  • Application: ELISA
  • Specificity: Cross Reactivity:
    Peptide YY (3-36) (Dog, Mouse, Pig, Rat), Peptide YY (1-36) (Dog, Mouse, Pig, Rat): 100%
    Neuropeptide Y (Porcine): 2.4%
    Peptide YY (1-36) (Human), Peptide YY (3-36) (Human), Neuropeptide Y (Human, Rat, Mouse), Pancreatic Polypeptide (Human), Amylin Amide (Human), Insulin (Human), Glucagon (Human), Substance P: 0%
  • Sample type: Serum and plasma
  • Sensitivity: 0.07 ng/ml
  • Standard Range: 0.01 - 100 ng/ml
  • Detection Range: 0.07 - 0.64 ng/ml
  • Conjugation: HRP