Search Result - Kits

  • Arg8 Vasopressin ELISA Kit
  • Cat. No: ARG83003
  • Reactivity: Hu, Ms, Rat, Dog, Sheep
  • Application: ELISA
  • Specificity: Cross-Reactivity:
    [Arg8]-Vasopressin (Human, Mouse, Rat, Ovine, Canine): 100%; [Arg8]-Vasotocin: 54%; [Lys8]-Vasopressin (Human, Rat, Mouse, Ovine), Deamino-[D-Arg8]-Vassopressin, Oxytocin, LH-RH, ACTH (Human), alpha-ANP (1-28) (Human, Canine), Met-Enkephalin, PACAP38 (Human, Ovine, Rat) and PACAP27-NH2 (Human, Ovine, Rat): 0%.
  • Sample type: Plasma (Sample extraction is recommended)
  • Sensitivity: 0.04 ng/ml
  • Standard Range: 0.01 - 100 ng/ml
  • Detection Range: 0.04 - 0.51 ng/ml
  • Conjugation: HRP
  • C5a ELISA Kit
  • Cat. No: ARG80868
  • Reactivity: Hu, Pig, Rb, R. Mk
  • Application: ELISA
  • Sample type: Plasma (EDTA, citrate) and urine.
  • Sensitivity: 20 pg/ml
  • Standard Range: 0.1 - 10 ng/ml
  • Conjugation: HRP
  • LH-RH / Gn-RH ELISA Kit
  • Cat. No: ARG80913
  • Reactivity: Hu, Ms, Rat, Pig
  • Application: ELISA
  • Specificity: Cross-reactivity: LH-RH (Human, Porcine, Rat) (100%);
    LH-RH (Lamprey) (0%);
    LH-RH (Salmon) (0%);
    [D-Trp6, Des-Gly10]-LH-RH Ethylamide (0%);
    [D-Ala6, Des-Gly10]-LH-RH Ethylamide (0%);
    GAP (Human) (0%);
    GRF (Human) (0%);
    ACTH (Human) (0%)
  • Sample type: Blood collection, Plasma extraction, Tissue extraction and CSF extraction
  • Sensitivity: 0.05 ng/ml
  • Standard Range: 0 - 25 ng/ml
  • Detection Range: 0.05 - 1.16 ng/ml
  • Conjugation: HRP
  • Irisin ELISA Kit
  • Cat. No: ARG81195
  • Reactivity: Hu, Ms, Rat, Dog
  • Application: ELISA
  • Specificity: Irisin, Recombinant (Human, Rat, Mouse, Dog): 100%
    Irisin (aa. 1-112) (Human, Mouse, Rat, Dog): 100%
    FNDC5, isoform 4 recombinant (Human, Mouse, Rat, Dog): 9%
    Irisin precursor, C-terminal 48mer: Human FNDC5 (aa. 165-212); Mouse, Rat FNDC5 (aa. 162-209): 0%
    Irisin (aa. 42-95) (Human, Mouse, Rat, Dog): 0%
  • Sample type: plasma (EDTA) and serum
  • Sensitivity: 1.91 ng/ml
  • Standard Range: 0.1 - 1000 ng/ml
  • Detection Range: 1.91 - 18.0 ng/ml
  • Conjugation: HRP
  • Glucagon ELISA Kit
  • Cat. No: ARG81293
  • Reactivity: Hu, Ms, Rat, Pig
  • Application: ELISA
  • Specificity: No significant cross-reactivity or interference with the factors below was observed:Glucentin-Related Polypeptide (aa 21-50), Glucagon-Like Peptide 1 (aa 92-128) and Glucagon-Like Peptide 2 (aa 146-178).
  • Sample type: Serum, plasma or cell culture supernatants.
  • Sensitivity: 30 pg/ml
  • Standard Range: 62.5 - 4000 pg/ml
  • Conjugation: HRP
  • Mouse/Rat Insulin (Ultra sensitive) ELISA Kit
  • publication_list (1 Publications)
  • Cat. No: ARG81295
  • Reactivity: Ms, Rat
  • Application: ELISA
  • Specificity: Mouse / Rat Insulin: 100%
    Hamster Insulin: Detected
    Rat C-peptide, Rat pancreatic polypeptide, Porcine glucagon, Human Insulin like growth factor-I and II: Not Detected
  • Sample type: Serum, plasma and cell culture supernatants.
  • Sensitivity: 50 pg/ml (5 µl sample volume); 5 pg/ml (100 µl sample volume)
  • Standard Range: 0.1 - 6.4 ng/ml
  • Conjugation: HRP
  • ALP / Alkaline Phosphatase Assay Kit
  • Cat. No: ARG81296
  • Reactivity: Hu, Ms, Rat, Mamm
  • Application: FuncSt
  • Specificity: p-nitrophenyl phosphate that is hydrolyzed by ALP into p-nitrophenol and seen as a yellow colored product and could be detect at 405 nm. This ALP activity kit measurement the color change at O.D. 405 nm for ALP activity analysis.
  • Sample type: Serum and plasma.
  • Sensitivity: 2 U/l
  • Detection Range: 5 µl serum or plasma sample: 2 - 800 U/l
  • AST / Aspartate Transaminase Assay Kit
  • Cat. No: ARG81297
  • Reactivity: Hu, Ms, Rat, Mamm
  • Application: FuncSt
  • Specificity: Aspartate aminotransferase (ASAT/AAT) facilitates the conversion of aspartate and alpha-ketoglutarate to oxaloacetate and glutamate. And then oxaloacetate and NADH are converted to malate and NAD by malate dehydrogenase. Therefore, the decrease in NADH absorbance at 340 nm is proportionate to AST activity.
  • Sample type: Serum and plasma.
  • Sensitivity: 2 U/l
  • Detection Range: 2 - 100 U/l